Page 115 - Softbound_Edition_19_en
P. 115

Solenoids                                                                                      Solenoid accessory
                                                                                                         Solenoids
 PD2-AMPLIFIER WITH ANALOGUE INTERFACE

 Command value scaling  F  X1-1  Signal recording  F  X1-1  F  X1-2  Amplifier with CANopen interface
 Versorgungs-
 Supply
 brown
 braun
 The command value can be applied as a voltage, current, digital, fre-  Furthermore, the „PD2“ amplifier electronics have a signal recording   Tension  X1-5
 spannung
 X1-5
 X1-5
 gray
  d'alimentation
 voltage
 grau
 quency or PWM signal. The scaling takes place via the parameter “In-  function. This, by means of PASO, enables the recording of various   ELECTRICAL SPECIFICATIONS
 F = Fuse slow
 F = Sicherung träge
 terface”. Furthermore, the command value can be monitored for a cable   system signals, such as command value, solenoid current, etc., which   F = Sécurité inerte  IP 67 acc. to EN 60 529  Dither   Frequency adjustable 4…500 Hz
            Protection class
 break. A dead band can also be set.  can be represented on a common time axis.  Supply voltage    8…32 V      Factory setting 80 Hz
            Residual ripple    < +/-5 %                                               Level adjustable 0…400 mA
 Fixed command value  Solenoid driver  Fuse    low                                    Factory setting 180 mA
 There is 1 fixed command value available, which can be selected via   A Pulse-Width-Modulated current output is available. A dither signal is   No-load current    approx. 20 mA   Temperature drift   <1 % at ∆T = 40 °C
 the digital input. This function has to be configurated before in PASO.  superimposed, whereby the dither frequency and the dither level are   Max. current   Digital inputs   1 input high-active, no pull-up/down
 USB/PASO  separately adjustable. The minimum (Imin) and maximum (Imax) cur-  USB/PASO  consumption   No-load current + 2,5 A per solenoid      Switching threshold high 6...32 VDC
 USB/PASO
 Ramp generator  rent can be adjusted. The solenoid output can also be configurated as       Switching threshold low 0…1 VDC
 Two linear ramps for up and down are available which can be adjusted   switching solenoid output. In this case, a power reduction can be ad-  Solenoid current:      Usable as frequency input
 0...1 VDC
 0...1 VDC
 0...1 VDC
 separately.  X1-3  weiss  justed.  X1-3  white  X1-3  blanc • Minimal current I     Adjustable 0…I   mA      (frequency 5...5000 Hz) and as PWM
 6...32 VDC  6...32 VDC  6...32 VDC  min  max
 Versorgungs-  F  X1-1  braun  Supply  F  X1-1  brown  Tension     F  X1-2  Factory setting 30 mA     input (automatic frequency recognition)
 Valve type  spannung  X1-5  grau  Optimisation of characteristic curve  X1-5  gray  d'alimentation  X1-5     Adjustable  I …2450 m A  USB interface   Via digital input
 voltage
                                      min
 Adjustment possibilities: switching solenoid or proportional solenoid.  An adjustable characteristic curve „Command value input – solenoid   • Maximal current I max  MP35/19x50-..-12, Factory setting 1360 mA      Requires the Wandfluh USB adapter

 Adapter
 F = Fuse slow
 F
 F
             F
 USB/PASO
 USB-PD2
 Versorgungs-  F = Sicherung träge  braun  current output“ enables an optimised (e.g. linearised) characteristic of   Tension  F = Sécurité inerte  MP35/19x50-..-24, Factory setting 680 mA  EMV
 X1-1
                    X1-2
 X1-1

 Supply
 brown
 Mode of operation „Command value unipolar/bipolar (1-Sol)  the hydraulic system.  X1-5  gray  d'alimentation      X1-5  MP45/23x50-..-12, Factory setting 1490 mA  Immunity   EN 61 000-6-2
 spannung
 X1-5
 voltage
 grau
 Dependent on a command value signal (voltage, current, digital, fre-      MP45/23x50-..-24, Factory setting 780 mA  Emission    EN 61 000-6-4
 0...1 VDC
 F = Sicherung träge
 quency or PWM), the solenoid is driven (e.g. 0….10V correspond to   Channel enabling  F = Fuse slow  F = Sécurité inerte  MPS60/31x72-..-12, Factory setting 2290 mA
 weiss
 X1-3

 6...32 VDC
 0….100 % command value, 0….+100 % command value correspond   As per factory setting, the device is enabled („on“). This „enable chan-      MPA60/31x72-..-12, Factory setting 2290 mA
 to Imin….Imax solenoid driver)  nel“ can be set to „on“, „off“ or „external“ (digital input) via PASO or via       MPS60/31x72-..-24, Factory setting 1140 mA
 USB/PASO  menu item.  USB/PASO  USB/PASO      MPA60/31x72-..-24, Factory setting 1140 mA
 Hints:
 0...1 VDC  USB/PASO  Digital input:   0...1 VDC  USB/PASO  0...1 VDC  USB/PASO
 if not wired, the state of the digital input is not defined
 6...32 VDC  X1-3  weiss  6...32 VDC  X1-3  white  6...32 VDC  X1-3  blanc
 Analogue input: if not wired, the voltage input will read 1.11 V constantly.
 X1-4
 0...1 VDC  X1-4  gelb  0...1 VDC  yellow  X1-4  jaune  BLOCK DIAGRAM
 0...1 VDC
 6...32 VDC  X1-2  Adapter  X1-3  weiss  6...32 VDC  X1-3  white  6...32 VDC  X1-3  blanc
 X1-2
 X1-2
 grün
 USB/PASO  USB-PD2  green  vert
 X1-5  grau  X1-5  grey  X1-5  gris  brown  X1-1
 0 %   0...1 VDC  100 %   Command value  +VCC
 Adapter
 0 V   USB/PASO  USB-PD2  X1-3  weiss
 10 V
 4 mA   6...32 VDC  20 mA   Analogue value
 0 mA   20 mA
 5 Hz   0...1 VDC  5000 Hz  X1-3  weiss
 - 10 V   6...32 VDC  10 V
                           grey   X1-5
            GND
 CONNECTION EXAMPLES
 X1-4  gelb  X1-4  yellow  X1-4  jaune      Internal      Supply               PWM                          Solenoid
 Analogue input with potentiometer
 Versorgungs-  F  X1-1  braun  Supply voltage  F  X1-1  brown  Tension  F  X1-2  supply
 Supply
 vert
 X1-2
 spannung  X1-5  grau  voltage  0...10 VDC  gray  grün X1-2  grün  d'alimentation  X1-2  green  0...10 VDC  X1-2  X1-2  vert
 X1-5
 X1-5 green
 X1-2
 0...10 VDC
 F
 F
 X1-5
 X1-4
 X1-2 X1-5
 Versorgungs-  F F = Sicherung träge  braun  Supply  F = Fuse slow  +/-10 VDC  X1-4  gelb X1-5  grau  Tension  +/-10 VDC  F = Sécurité inerte  grey  +/-10 VDC  X1-4  jaune  gris  CAN-High  yellow  X1-4
 yellow
 X1-1
 X1-1
 brown
 grau
 gris
 grey
 X1-5
 X1-5
 X1-5
 spannung  X1-5  grau  voltage  X1-5  gray  d'alimentation  X1-5
 X1-2  grün  X1-2  green  X1-2  vert
 F = Sicherung träge  F = Fuse slow  F = Sécurité inerte                        A/D
 X1-5  grau  X1-5  grey  X1-5  gris
                           green  X1-2
 Digital input as function input  Analogue input current with external current source  CAN-Low
 USB/PASO  USB/PASO  USB/PASO
 0...20 mA  X1-2  grün  0...20 mA  X1-2  green  0...20 mA  X1-2  vert
 4...20 mA  X1-5  grau  4...20 mA  X1-5  grey  4...20 mA  X1-5  gris
 USB/PASO  USB/PASO  USB/PASO
 0...1 VDC  0...1 VDC  0...1 VDC
 X1-3
 blanc
 6...32 VDC  X1-3  weiss  6...32 VDC  X1-3  white  6...32 VDC  Analogue input voltage with external voltage source
 0...1 VDC  0...1 VDC  0...1 VDC  white
 blanc
 white
 X1-2
 6...32 VDC  X1-3  weiss  6...32 VDC  X1-3  0...10 VDC  6...32 VDC  grün  X1-3  0...10 VDC  X1-2  green  0...10 VDC  X1-2  vert  Digital Input  X1-3
 +/-10 VDC
 X1-5
 Adapter  CAN-Low  +/-10 VDC X1-2  grün  X1-5  grau  CAN-Low  X1-2  green  +/-10 VDC  CAN-Low X1-5  gris  X1-2  vert
 grey
 USB/PASO  USB-PD2
 0...10 VDC X1-4
 CAN-High
 green
 0...10 VDC
 X1-2
 Adapter  Digital input as USB interface  gelb  X1-2  grün  CAN-High  X1-4  yellow  0...10 VDC  CAN-High  vert  X1-4  jaune
 X1-2
 USB/PASO  USB-PD2  +/-10 VDC  X1-5  grau  +/-10 VDC  X1-5  grey  +/-10 VDC  X1-5  gris
 0...1 VDC  VCC
 6...32 VDC  X1-3  weiss  Adapter        Push-buttons                                      7 segment
 0...1 VDC  brown  VCC+  USB-PD2                                     FLASH                 display
 6...32 VDC  X1-3  weiss  PC  USB  USB - Adapter  ON  DIG  white  DigInp  RAM
 TX
 0...20 mA
 X1-2
 PASO  0...20 mA  RX  OV  grün  grey  PD2  X1-2  green  0...20 mA  X1-2  vert
 4...20 mA  X1-5  grau  GND  4...20 mA  X1-5  grey  4...20 mA  X1-5  gris  PASO / USB
 0...20 mA  X1-2 GND grün  0...20 mA  X1-2  green  0...20 mA  X1-2  vert
 4...20 mA  X1-5  grau  4...20 mA  X1-5  grey  4...20 mA  X1-5  gris
 X1-4  gelb  X1-4  yellow  X1-4  jaune
   Plug
 X1-2  grün  X1-2  green CAN-Low  X1-2  grün  X1-2  vert  CAN-Low  X1-2  green  CAN-Low  X1-2  vert
 X1-4  gelb  X1-4  yellow    USB type B   Screw Terminal
 jaune
 X1-4
 X1-4
 X1-4
 X1-4
 gelb
 CAN-High
 CAN-High
      jaune
 yellow
 X1-2 X1-5
 X1-2 X1-5  grau  X1-2 X1-5  grey CAN-High  Tel.  +41 33 672 72 72   vert  gris  CAN-Low  X1-2  green  Data sheet no.  X1-2  vert  Wandfluh AG   Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   Illustrations not obligatory   Data sheet no.
 grün
 green
 E-mail:  sales@wandfluh.com
 Wandfluh AG
 Illustrations not obligatory
 CAN-Low
 X1-2
 grün
 CAN-Low
 Internet:  www.wandfluh.com
 grey
 X1-5
 X1-5  grau  X1-5 Postfach   Fax  +41 33 672 72 12  gris  Data subject to change   1.1-330E 4/7  Postfach   Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   1.1-330E 5/7
 CAN-High
 CAN-High

 CH-3714 Frutigen  X1-4  gelb  CAN-High  X1-4  yellow  Edition 21 20  X1-4  jaune  CH-3714 Frutigen      Edition 21 20
                                                                                                            Page 115
 0...10 VDC  X1-2  grün  0...10 VDC  X1-2  green  0...10 VDC  X1-2  vert
 +/-10 VDC  X1-5  grau  +/-10 VDC  X1-5  grey  +/-10 VDC  X1-5  gris
 0...10 VDC  X1-2  grün  0...10 VDC  X1-2  green  0...10 VDC  X1-2  vert
 +/-10 VDC  X1-5  grau  +/-10 VDC  X1-5  grey  +/-10 VDC  X1-5  gris
 0...20 mA  X1-2  grün  0...20 mA  X1-2  green  0...20 mA  X1-2  vert
 4...20 mA  X1-5  grau  4...20 mA  X1-5  grey  4...20 mA  X1-5  gris
 0...20 mA  X1-2  grün  0...20 mA  X1-2  green  0...20 mA  X1-2  vert
 4...20 mA  X1-5  grau  4...20 mA  X1-5  grey  4...20 mA  X1-5  gris
 CAN-Low  X1-2  grün  CAN-Low  X1-2  green  CAN-Low  X1-2  vert
 CAN-High  X1-4  gelb  CAN-High  X1-4  yellow  CAN-High  X1-4  jaune
 CAN-Low  X1-2  grün  CAN-Low  X1-2  green  CAN-Low  X1-2  vert
 CAN-High  X1-4  gelb  CAN-High  X1-4  yellow  CAN-High  X1-4  jaune
   110   111   112   113   114   115   116   117   118   119   120